Introduction
In industrial and commercial fire-protection networks, valves safeguard people, property, and critical processes by controlling the direction, pressure, and isolation of water flow. While ball valves excel at quick shut-off, gate valves offer full-bore isolation, and precision control valves fine-tune hydraulic balance, the humble check valve plays an equally decisive role: it prevents destructive backflow that can flood pump houses, trigger false alarms, and contaminate potable or process water supplies. In firefighting systems—where reliability during a genuine emergency matters more than in any other application—choosing a proven, code-listed swing check valve is a non-negotiable design decision.
The Tyco Fire Model CV-1F Grooved End Swing Check Valve meets that challenge head-on. Engineered for DN 50 – DN 300 (2″ – 12″) pipe sizes and rated to 300 psi (20.7 bar) working pressure, this compact unit combines rapid forward flow with dependable backflow prevention. Its robust ductile-iron body, stainless-steel hinge pin, and EPDM-faced bronze disc resist corrosion, erosion, and water hammer, while the integral grooved ends enable lightning-fast installation with industry-standard couplings. Certified by UL, C-UL, and FM, the valve delivers peace of mind to engineers, contractors, insurance auditors, and facility owners who refuse to compromise on fire safety.
Comprehensive Product Description
The Tyco CV-1F is a swing-type check valve: a clapper disc, hinged on a durable stainless-steel pin, swings freely out of the flow path when water moves in the forward direction. Should the flow cease—or, worse, attempt to reverse—the disc pivots back onto a resilient seat, sealing bubble-tight against a machined bronze ring. This simple, gravity-assisted mechanism has proven itself for more than a century, yet Tyco’s modern enhancements elevate performance to contemporary expectations.
Grooved End Convenience
By machining AWWA C-606-compatible grooves directly into the body, Tyco allows contractors to join the valve with two-bolt couplings in seconds—eliminating alignment headaches, hot-work permits, and the torque-wrench rituals associated with flanges. The result is faster installation, easier maintenance, and the flexibility to rotate or replace the valve without disturbing adjacent piping.
Compact, Flow-Friendly Body
Traditional swing check valves often suffer from bulky profiles and turbulent flow paths that waste energy. Tyco’s engineers refined the casting geometry to provide a smooth interior contour, minimising pressure drop even at the upper end of the 300 psi rating. In a world where pumps consume vast electrical power, every avoided foot of head results in measurable operating-cost savings.
Materials of Construction
| Component | Material | Function & Benefit |
|---|---|---|
| Body & Cover | ASTM A536 ductile iron, epoxy coated | High strength-to-weight ratio, corrosion resistance |
| Clapper Disc | Bronze with replaceable EPDM insert | Corrosion-proof seating, field-replaceable elastomer |
| Seat Ring | Bronze | Machined accuracy, galling resistance |
| Hinge Pin | Type 304 stainless steel | Maintains alignment under water-hammer loads |
| Cover Gasket | EPDM/NBR | Wide temperature tolerance, easy replacement |
| Exterior Finish | Fusion-bonded epoxy (red) | UV-stable protection for outdoor or pump-room service |
All wetted materials are compatible with fire-water additives, municipal chlorination, and typical process-water chemistries, ensuring long service life in harsh industrial atmospheres.
Technical Specifications
| Parameter | Value |
|---|---|
| Size Range | DN 50 – DN 300 (2″ – 12″) |
| Working Pressure | 300 psi (20.7 bar) |
| End Connections | Grooved per AWWA C-606 |
| Flow Direction | Horizontal (standard) or vertical (flow up) |
| Maximum Temperature | 120 °C (EPDM seat) / 82 °C (NBR seat) |
| Approvals & Listings | UL, C-UL, FM |
| Inspection Access | Bolted cover with captive nuts |
| Drain / Test Tapping | ½” NPT boss (sizes DN 100 – DN 300) |
| Flow Coefficient (Cv) | 82 (DN 50) to 4 600 (DN 300) |
The valve ships hydro-tested at 1.5 × working pressure and is individually serialized for full traceability—a critical factor during fire-system audits.
Key Features and Benefits
Bubble-Tight Backflow Prevention
The EPDM-faced disc seals against the bronze seat ring with minimal seating force, guaranteeing no reverse leakage that could jeopardise system readiness or dilute foam concentrates in combined agent systems.
Low Maintenance Downtime
A single top cover secured by stainless-steel cap-screws permits rapid internal inspection. Technicians can replace the disc insert and gasket in minutes, returning the valve to duty without cutting pipe or draining the entire riser.
Energy-Efficient Hydraulics
A streamlined body cavity and thin, hydrodynamically profiled disc reduce turbulence, improving pump efficiency and sustaining sprinkler hydraulics—the lifeblood of any suppression network.
Corrosion-Resistant Build
Fusion-bonded epoxy inside and out shields the ductile-iron casting from raw-water corrosion, while bronze and stainless wetted parts shrug off micro-biologically influenced corrosion (MIC) that can plague lesser valves.
Universal Orientation
Unlike lift check valves, the swing mechanism operates reliably in horizontal mains or vertical risers (flow upward), offering layout flexibility for architects and BIM coordinators.
Grooved-End Versatility
The valve integrates seamlessly with steel, stainless, or ductile-iron pipe using rigid or flexible couplings—ideal for seismic zones or pump-house skid packages that demand vibration tolerance.
Industrial Applications
Fire Pump Discharge & Bypass Lines
After a diesel or electric fire pump stops, residual head can drive water backward into the pump casing, risking impeller spin in reverse. Installing the CV-1F immediately downstream prevents damaging reverse rotation.
Zone Isolation in High-Rise Buildings
Urban towers often employ pressure-reducing valves and staged zones. A swing check in each riser maintains unidirectional flow, protecting pressure regulators and preventing supply crossover.
Warehouse & Logistics Hubs
Long branch lines increase water-hammer risk when loads shift. The Tyco check valve’s smooth closure mitigates water hammer, reducing pipe-support fatigue and maintenance calls.
Data Centre Cooling Loops
Mission-critical facilities rely on dual-purpose mains for cooling and fire protection. Non-slam check performance ensures sudden chiller pump trips don’t back-feed fire-pump jockey circuits.
Petrochemical Process Water
In refineries, firefighting headers interconnect with process-water networks. The check valve isolates firefighting foam from contamination and meets FM Global insurance requirements.
Distribution and Stock Availability
As a premier valve distributor and long-standing valve stockist for Tyco Fire & Building Products across Southeast Asia, we maintain extensive inventory in DN 50, DN 100, and DN 150 sizes—complete with coupling gaskets and groove-inlet transition pieces.
-
Ready Stock: Over 500 units across key diameters stored in Jakarta, Surabaya, and Batam hubs.
-
Rapid Dispatch: Same-day shipping for orders confirmed before 14:00 local time, with air-freight options for critical shutdowns.
-
Technical Support: NICET-certified staff provide hydraulic calculations, submittal packages, and BIM models for consultant approval.
-
Turnkey Bundles: Combine check valves with Tyco OS&Y gate valves, butterfly control valves, or electrically monitored ball valves to create code-compliant riser kits.
Every valve ships with original factory hydro-test certificates, material trace letters, and a 12-month warranty—assuring project owners of genuine Tyco quality.
Why Choose the Tyco CV-1F Over Generic Swing Check Valves
Proven Certification
UL, C-UL, and FM listings guarantee the valve meets stringent fire-protection performance criteria enforced worldwide—something unlisted look-alikes cannot replicate.
300 psi Future-Proofing
As building heights rise and pump pressures climb, the CV-1F’s 20.7-bar rating ensures survival even if system upgrades push beyond today’s norms.
Grooved End Speed
Field labour time drops dramatically when installers use grooved couplings instead of flanged joints—a critical saving on fast-track data-centre builds and tenant improvements.
Consistent Torque & Lift
Tyco’s precision hinge design prevents disc flutter and ensures repeatable opening pressure, protecting upstream jockey pumps from unnecessary run cycles.
Lifecycle Economy
Fewer emergency callouts, reduced energy costs, and longer seat life add up to a lower total cost of ownership—vital for facility managers juggling tight OPEX budgets.
Call to Action
Backflow events aren’t just inconvenient—they can cripple fire-suppression readiness. Secure your system with the Tyco Fire CV-1F Grooved End Swing Check Valve and gain certified protection, fast installation, and decades of dependable performance.
As your trusted valve distributor and responsive valve stockist, we deliver genuine Tyco solutions—on time, every time—so your fire-protection system never misses a beat.