TYCO FIRE WET SYSTEM RC-1 – Tyco

Feature Description
Product Name Tyco Fire Wet System Valve with RC-1 Retard Chamber
Valve Type Alarm Check Valve with Retard Chamber (Wet-Pipe System)
Model AV-1-300 (Valve), RC-1 (Retard Chamber)
Size Range DN 100–200 (4″–8″)
Pressure Range 20–300 psi (1.4–20.7 bar)
Application Wet automatic sprinkler systems
Alarm Function Pressure-operated alarm port with delay control (RC-1)
Mounting Options Vertical or Horizontal
Connection Type Flanged or Grooved Ends
Retard Chamber Purpose Prevents false alarms due to pressure surges
Material – Body Ductile Iron / Cast Steel
Material – Trim Stainless Steel
Approval & Listings FM, VdS, LPCB
Operation Automatic – No external power required
Typical Installations High-rise buildings, data centers, warehouses, healthcare, industrial facilities
Distributor Support Ready stock, fast shipping, technical support, complete accessories
Category: Brand:

Tyco Fire Wet System Valve & Model RC-1 Retard Chamber

High-Reliability Alarm Check Valve Assembly for Wet-Pipe Automatic Sprinkler Systems


Introduction: Valves as the Nerve Center of Fire-Protection Infrastructure

In the broader industrial universe—power generation, petrochemical refining, warehousing, and high-rise property management—valves are the silent guardians of flow control. A ball valve may offer quick isolation, a gate valve provides full-bore shut-off, a check valve eliminates reverse flow, and a precision control valve fine-tunes differential pressure. Yet in wet-pipe sprinkler networks—by far the most common fire-suppression architecture worldwide—no component is more mission-critical than an alarm check valve coupled with a retard chamber. These devices detect the faintest rise in waterflow caused by a single sprinkler head fusing, while screening out false alarms from transitory line-pressure spikes typical of public mains.

The **Tyco Fire Wet System Valve Series—anchored by the Model AV-1-300 Alarm Check Valve and the Model RC-1 Retard Chamber—**epitomises this life-safety function. Engineered for a maximum working pressure of 300 psi (20,7 bar) and factory-listed by FM, VdS, and LPCB, this assembly provides rock-solid reliability, regulatory compliance, and long service life in any climate zone or industrial vertical.


Complete Product Description

Alarm Check Valve: Model AV-1-300

At the heart of the Tyco wet-system riser sits the AV-1-300 Alarm Check Valve. Designed for DN100–DN200 (4″–8″) pipe sizes, this cast-steel or ductile-iron body valve acts as a one-way gateway: water can enter the sprinkler grid from the supply side, but reverse flow is prevented by a clapper-style check mechanism. When a sprinkler head opens under fire conditions, flow lifts the clapper from its seat, instantly diverting a portion of water into an alarm port that triggers an electric pressure switch and/or a hydraulic fire gong.

Key attributes include:

  • 300 psi (20,7 bar) rating—matching or exceeding the most demanding insurance specifications.
  • Horizontal or vertical mounting—simplifying riser room layouts.
  • Grooved or flanged ends—compatibility with both AWWA C606 couplings and ANSI/DIN flange patterns.
  • Low differential lift pressure—ensuring rapid alarm actuation even on long or hydraulically remote branch lines.

Retard Chamber: Model RC-1

While the alarm check valve is sensitive by design, municipal water supplies are notorious for pressure transients caused by pump cycling, street-valve maintenance, or demand fluctuations. Left unconditioned, these pressure waves could nudge the clapper just enough to activate the alarm circuit—creating nuisance trips and eroding confidence in the fire-safety system.

The Tyco Model RC-1 Retard Chamber solves this by acting as a hydraulic “shock absorber.” Installed in the alarm line between the AV-1-300 valve and the pressure switch/gong, the chamber temporarily stores water displaced by minor pressure reversals. Only sustained flow—typically ten seconds or longer—will fill the RC-1 and generate sufficient pressure to close the alarm switch, thus discriminating between real fire events and harmless main-line pressure noise.

Constructed from corrosion-resistant steel or ductile iron and factory-tested to the same 300 psi envelope, the RC-1 integrates seamlessly into either new builds or retrofit projects. Its threaded inspection plug allows easy flushing, and optional trim kits simplify code-compliant installation.

Assembly Materials & Construction

Component Material Function / Benefit
Valve Body & Cover Ductile Iron / Cast Steel Withstands high pressure and water hammer
Clapper & Seat Ring Stainless Steel Corrosion resistance, long sealing life
Retard Chamber Shell Epoxy-Coated Steel Provides corrosion protection against treated or raw water
Trim & Fittings Galvanized / Stainless Minimises rust, eases maintenance
Elastomeric Seals EPDM / Nitrile Maintains tight seal over broad temperature range

Functional Advantages & Performance Highlights

  1. True Double-Duty Protection – By combining a UL/FM alarm check valve with a calibrated retard chamber, the Tyco assembly virtually eliminates false alarms while guaranteeing rapid fire detection.
  2. High Hydraulics, Low Loss – A full-flow body casting and streamlined clapper reduce pressure loss, keeping sprinkler hydraulics within NFPA and EN design curves.
  3. Code & Insurance Compliance – FM, VdS, and LPCB approvals satisfy global jurisdictions, while the 300-psi rating meets high-rise and water-mist system pressures.
  4. Serviceability – Hinged clapper cover permits internal inspection without cutting the pipe; RC-1 drain plug allows quick sediment removal.
  5. Scalable Automation – The alarm port supports dual pressure switches for redundant monitoring or remote annunciation via building-management systems.

Typical Applications

Commercial & High-Rise Buildings

Tall towers demand elevated pump pressures; the AV-1-300/RC-1 pair safely accommodates static pressures up to 20,7 bar while filtering out elevator-pump reversals that might otherwise fake a fire signal.

Warehousing & Logistics Hubs

Large-diameter mains and long branch lines in distribution centres benefit from the valve’s low hydraulic resistance and precision alarm sensitivity, ensuring early detection across massive floor areas.

Petrochemical & Energy Facilities

Chemical plants and turbine halls often experience water-hammer surges from jockey pumps. The retard chamber’s pressure-dampening capacity prevents nuisance alarms that might halt production.

Data Centres & Clean Rooms

Mission-critical sites rely on immediate yet accurate alarms to coordinate suppression and server shut-down sequences. Tyco’s solution balances ultra-fast response with false-trip immunity.

Healthcare & Educational Campuses

Hospitals and universities require minimal disruption. The Tyco wet system valve assembly’s reliability under fluctuating municipal supply keeps maintenance calls—and patient/student evacuations—to a minimum.


Distribution, Stock, and Service Excellence

As an authorised valve distributor and long-standing valve stockist for Tyco Fire & Building Products, we maintain multi-tier inventory to meet tight construction schedules and emergency retrofit scenarios.

  • Ready Stock — DN100, DN150, and DN200 alarm check valves and retard chambers in both grooved and flanged ends.
  • Same-Day Dispatch — Orders confirmed by 14 : 00 Jakarta time leave our warehouse the same day, with air-freight options for critical shutdowns.
  • Trim & Accessories — Complete installation kits, pressure switches, hydraulic gongs, and test/inspector’s screws available off the shelf.
  • Technical Support — NICET-certified fire-protection specialists assist with hydraulic calculations, riser schematics, and compliance documentation.
  • On-Site Commissioning — Field technicians can supervise hydrostatic tests, flow alarms, and quarterly inspections, ensuring your wet-pipe system is code-ready from day one.

Our holistic supply chain means you receive genuine Tyco components, backed by factory warranties and full traceability—critical for insurance audits and authority – having-jurisdiction (AHJ) approvals.


Why Choose Tyco Fire Wet System Valves?

  • Global Brand Confidence – Tyco, a Johnson Controls company, has protected assets for over a century, from NASA launch pads to world-class museums.
  • All-Hazards Engineering – Each valve undergoes hydrostatic, flow sensitivity, and pressure-pulse testing, guaranteeing performance in both freezing Nordic winters and equatorial humidity.
  • Future-Ready Integration – Compatible with modern addressable panels, IoT sensors, and building-management platforms, supporting predictive maintenance and digital twins.
  • Lower Total Cost of Ownership – Fewer nuisance trips mean reduced overtime for reset crews, minimal disruption to operations, and preservation of stakeholder confidence.

Call to Action: Protect What Matters—Specify Tyco Today

Fire never sends an invitation. Equip your facility with the Tyco Model AV-1-300 Alarm Check Valve and RC-1 Retard Chamber to guarantee fast, reliable detection without the headache of false alarms.

  • Immediate pricing & stock confirmation
  • Engineering submittals and BIM files
  • On-site start-up or quarterly service contracts

As your trusted valve distributor and dedicated valve stockist, we deliver more than products—we deliver safety, compliance, and peace of mind, on time and every time.